Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(9)2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38730967

RESUMO

Stress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone. Using the three-dimensional ARAMIS camera system, surface strain in the peri-implant bone area was compared under simulated masticatory forces of 300 N in axial and non-axial directions for titanium implants and zirconia implants. The investigated titanium implants led to a more homogeneous stress distribution than the investigated zirconia implants. Non-axial forces led to greater surface strain on the peri-implant bone than axial forces. Thus, the implant material, implant system, and direction of force could have a significant influence on biomechanical processes and osseointegration within the peri-implant bone.

2.
Dent J (Basel) ; 12(4)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38668006

RESUMO

The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed-automatically and manually-with the scanbody geometries stored within the software's shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.

3.
Tomography ; 9(4): 1515-1525, 2023 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624114

RESUMO

Orbital floor fractures (OFFs) are common injuries of the midface and may result in long-term complications. The aim of this study was to compare two restoration materials, PDS foils and titanium meshes, with regards to (1) clinical outcome and (2) reduction in orbital volume. The monocentric discovery cohort was analyzed retrospectively and included 476 patients with OFFs treated between 2010 and 2020. A subcohort of 104 patients (study cohort) with isolated OFFs and available high-resolution imaging material was used for volume measurements. Postoperative complications were not significantly different between patients treated with different restoration materials. Prevalence of revision surgery was significantly higher in patients treated with thick PDS foils (25 mm). OFFs treated with PDS foils and titanium meshes showed a significant reduction in orbital volume (p = 0.0422 and p = 0.0056, respectively), however, this volume decrease was significantly less pronounced in patients treated with PDS foils alone (p = 0.0134). Restoration using PDS foil in an isolated OFF reduces the orbital volume to a lesser extent than titanium mesh. Class III patients according to the classification of Jaquiéry with a missing bony ledge medial to the infraorbital fissure particularly benefit from restoration with PDS foils due to a lower reduction in the orbital volume. Regarding short- and long-term postoperative complications, a PDS foil thickness of 0.15 mm appears equivalent to titanium mesh in the treatment of OFFs.


Assuntos
Complicações Pós-Operatórias , Titânio , Humanos , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico por imagem
4.
Tomography ; 9(2): 579-588, 2023 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-36961006

RESUMO

Orbital floor fractures represent a common fracture type of the midface and are standardly diagnosed clinically as well as radiologically using linear measurement methods. The aim of this study was to evaluate the accuracy of diagnostic measurements of isolated orbital floor fractures based on two-dimensional (2D) and three-dimensional (3D) measurement techniques. A cohort of 177 patients was retrospectively and multi-centrically evaluated after surgical treatment of an orbital floor fracture between 2010 and 2020. In addition to 2D and 3D measurements of the fracture area, further fracture-related parameters were investigated. Calculated fracture areas using the 2D measurement technique revealed an average area of 287.59 mm2, whereas the 3D measurement showed fracture areas with a significantly larger average value of 374.16 mm2 (p < 0.001). On average, the 3D measurements were 1.53-fold larger compared to the 2D measurements. This was observed in 145 patients, whereas only 32 patients showed smaller values in the 3D-based approach. However, the process duration of the 3D measurement took approximately twice as long as the 2D-based procedure. Nonetheless, 3D-based measurement of orbital floor defects provides a more accurate estimation of the fracture area than the 2D-based procedure and can be helpful in determining the indication and planning the surgical procedure.


Assuntos
Fraturas Orbitárias , Humanos , Estudos Retrospectivos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Órbita/cirurgia , Tomografia Computadorizada por Raios X/métodos
5.
BMC Oral Health ; 20(1): 345, 2020 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-33256686

RESUMO

BACKGROUND: The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years. METHODS: The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.6). The individual post-examination models were compared to the baseline model and deviations calculated in the sense of the largest, punctual loss of material in millimeters ("minimal distance"), the average abrasion in millimeters ("mean distance"), and the volume decrease in cubic millimeters ("integrated distance"). Statistical analyses were performed using the Wilcoxon sign rank test or mixed regression models. Multiple testing was considered by Benjamini-Hochberg correction. The significance level was set at 0.05. RESULTS: We found steadily increasing wear of the ceramic. The average volume decrease was significant (P < 0.001) at 3 years and 10 years (- 3.25 mm3 and - 8.11 mm3, respectively). CONCLUSIONS: The results of this study indicate that the rate of volume loss in feldspathic-ceramic-veneered zirconia frameworks in the posterior region increases significantly over time. An increasing frequency of parameters was observed, particularly in the second half of the study period. However, the use of this class of materials can be considered clinically acceptable. Trial registration This study is registered in DRKS - German Clinical Trials Register with the register number DRKS00021743. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021743.


Assuntos
Porcelana Dentária , Zircônio , Cerâmica , Humanos , Teste de Materiais , Propriedades de Superfície
6.
J Prosthodont ; 29(4): 309-314, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31802574

RESUMO

PURPOSE: Sufficient data are not currently available on how the various geometries of scan bodies and different scan strategies affect the quality of digital impressions of implants. The purpose of this study was to present new data on these two topics and give clinicians a basis for decision making. MATERIALS AND METHODS: A titanium master model containing three Nobelreplace Select™ implants (Nobelbiocare Services AG, Zurich, Switzerland) was digitized using an ATOS industrial noncontact scanner. Digitization was repeated three times with different types of scan bodies integrated into the implants: ELOS A/S, nt-trading GmbH, and TEAMZIEREIS GmbH. These three scans served as virtual master models. The titanium master model was then scanned with the TRIOS3© digital intraoral scanner (ELOS A/S, Copenhagen, Denmark), which was used for two different scanning strategies. Strategy A was a one-step procedure that included both the titanium master model and the integrated scan bodies. Strategy B comprised two steps. First, a digital overlay was performed with a scan of the titanium master model without integrated scan bodies. A second scan was performed with the titanium master model and integrated scan bodies. By repeating both strategies 10 times for each type of scan body, 60 scans were generated and the corresponding standard tessellation language data sets overlaid with the corresponding virtual master model. Deviations in the resulting superimpositions were calculated and evaluated separately in the individual axes (x, y, z) and in three-dimensional space (Euclidean distance). Statistical evaluation was performed using the R-project software. Level of significance was determined at p ≤ 0.05. RESULTS: With regard to the geometry of the scan bodies, strategy A significantly influenced the accuracy of the digital implant impression in regards to Euclidean distance (p = 0.003). No significant difference was found for strategy B in this context. Comparing the two scan strategies revealed that strategy A achieved significantly higher accuracy overall (p = 0.031). CONCLUSION: The quality of digital intraoral impressions seems to be influenced by both the geometry of the scan body and the scan strategy. For clinical practice, the one-step scan strategy seems beneficial. Furthermore, the scan bodies of ELOS A/S showed a potential clinical advantage.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Materiais para Moldagem Odontológica , Imageamento Tridimensional , Modelos Dentários , Suíça
7.
Cancer Biomark ; 24(1): 19-30, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30594916

RESUMO

BACKGROUND: Altered expressions of miR-186, miR-494 and miR-3651 in whole blood of OSCC patients have already been demonstrated. However, nothing is known about their expression in tumor tissues. This study aimed at evaluating differences in miRNA expression in OSCC tissues compared to healthy oral mucosa and at checking if the altered expression is reflected in corresponding blood. METHODS: In 53 OSCC and 40 healthy mucosal tissues the expression of miR-186, -494 and -3651 was determined by RT-qPCR and expression levels were compared between the groups. The altered expression in tissues was compared with that determined for corresponding blood. MiR-3651 target genes were identified using TargetScan software. RESULTS: Differential expression of miR-186 and miR-494 could not be observed in tumor tissues compared to normal mucosa (pmiR-186= 0.13; pmiR-494= 0.35). Contrary to the detected upregulation of the miR-3651 in the blood of OSCC patients, a significant downregulation was observed in OSCC tissues. A significant correlation between underexpression and diagnosis was ascertained (p= 0.0001). 1710 possible target genes of miR-3651 were identified. CONCLUSIONS: Decreased expression of miR-3651 in OSCC tissues may be a diagnostic biomarker. The opposite change in expression level in the blood might indicate different functions of this miRNA in circulation and tissue.


Assuntos
Biomarcadores Tumorais , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/genética , MicroRNAs/genética , Neoplasias Bucais/diagnóstico , Neoplasias Bucais/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Masculino , MicroRNAs/sangue , Pessoa de Meia-Idade , Neoplasias Bucais/sangue , Gradação de Tumores , Estadiamento de Neoplasias , Especificidade de Órgãos , Interferência de RNA , Curva ROC , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...